VME Bus Platform

 

General Specifications

Maximum Inrush Currents:
Limited to six times maximum peak
operating current.

Turn On Time: Soft start.

Hold Up Time: 20 msec. at nominal
line voltage and full load measured
from last AC crest.

Line and Load Regulation Combined:
V1 ±1.0%     Minimum Load
V2 ±5.0%        to
V3 ±5.0%     Full Load
Note: ±1.0% All outputs on VME500 only.

Minimum Load: 20% on V1 output with
0-50% on V2/V3 outputs.

Output Noise: 100mV, peak to peak
using scope termination.

Output Ripple:
1.0% or 50 mV, whichever is greater.

Output Response Time:
400usec maximum for 25% load step to
recover to within 1% of output voltage. Excursion during 25% load change to be
6% measured at 75% load to ±25%.

Storage Temperature: -40°C to +85°C.

Temperature Coefficient of Output
Voltages:
0.02% per °C maximum on V1
output only.

Efficiency:   75% typical.

Over Voltage Protection - V1 Only:
Set between 115%-135% of nominal
output voltage. Power must be manually
recycled after over voltage trip.

Isolation: V1 is fully isolated
from V2/V3 outputs and from
chassis up to 300 VDC.

Operating Temperature:
0°C-40°C Convection cooling. 0°C-50°C with 15 CFM forced air
cooling. All models 0°C-70°C
derate 2.5% per °C over maximum
allowed ambient temperature. VME500 - 0°C-50°C with 100CFM
forced air cooling.

Current Limiting Protection:
Automatic restart when overload or
short is removed. Adjusted to 105%
-140% of maximum rated current.

Remote Sensing: Eliminates the
effect of output lead resistance
on regulation, up to 0.25V lead
drop. Open sense lead protection
provided only on V1 output.

Reverse Voltage Protection:
Outputs protected against applied
reverse voltages.

Brown-Out Protection: Outputs
maintained down to input line
voltages of  85 or 170 VAC without
shutdown or damage.

Thermal Protection: Optional
Thermal Shut-down. Power must be
manually recycled after trip.

Parallel/Power-Sharing Operation:
Units can be configured to operate
in parallel with current sharing on
V1 outputs. VME200 has current
sharing on all three outputs. N+1
redundancy is optional. VME500 has
current sharing and N+1 capability.

Logic Interfaces:
VMEbus compatible power fail
signal (POWER FAIL).

Condition Indicators:
On/off power LED.

VME500 Front Panel Operations:
On/off power LED, output indicators
LED, test points and voltage
adjustment for all outputs are
located on the front panel.

Safety Specifications:
Designed to meet UL 1950
EMI/RFI - FCC 2780 Part 15 Class A

MTBF:
Estimated hours at 25°C, full load. VME100     200,000 hours
VME200     140,000 hours
VME500       60,000 hours

 

Output Connections

P1 Connector

VME Bus P1 Output Connector
Pin No. VME100 SERIES VME200 Series VME500 Series
4 V1 V2 Current Share V1
6 V1 V3 Current Share V1
8 V1 Return V2 V1
10 V1 Return V2 Return V1
12 V2 V3 V1
14 V2/V3 Return V3 Return V1
16 V3 No Connect V1
18 V1 Current Share No Connect V1
20 Power Fail V1 Signal Common V1 Return
22 V1 Remote Sense AC Fail V1 Return
24 No Connect System Reset V1 Return
26 AC/DC Line V1 Current Share V1 Return
28 No Connect +V1 Sense V1 Return
30 AC/DC Return -V1 Sense V1 Return
32 Chassis Ground Chassis Ground V1 Return

P2 Connector

VME Bus P2 Output Connector
Pin No. VME100 SERIES VME200 Series VME500 Series
4   V1 V2
6   V1 V2
8   V1 V2 Return
10   V1 V2 Return
12   V1 Return V3 Return
14   V1 Return V3 Return
16   V1 Return V3
18   V1 Return V3
20   No Connect No Connect
22   No Connect No Connect
24   No Connect No Connect
26   AC/DC Line No Connect
28   No Connect AC Return
30   AC/DC Return AC Line
32   Chassis Ground Chassis Ground
 

 

 

 

 

 

© Copyright 2007 Tri Source Inc., all rights reserved